st-5666-2004
360° (1) Interactive (0)

Product features

Easy to install
Three wire connection to the transmitter's explosion-protected spring terminals creates a very quick and reliable electrical connection. Available with an extra large body enabling the installation of specialised cable such as SWA is greatly simplified.
One-man-calibration
Maintenance of the PEX 3000 is very simple, and can be conducted by opening the housing without declassifying hazardous areas. A simple two button controlled digital display guides the user through procedures without the need for hand held terminals.
Comprehensive explosion protection
The Dräger PEX 3000 has been approved in accordance with the ATEX directive for ambient temperatures between -40 and +65 °C Approval is for potentially explosive gas and dust atmospheres (zones 1, 2, 21 and 22). In addition, the PEX 3000 is measurement performance approved in accordance with EN 61779-1, EN 61779-4 and EN 50271 ATEX harmonised standards.
The detection of low concentrations
The transmitter PEX 3000 Type XTR 0010 is equipped with a particularly low-drift sensor. This enables reliable detection of low gas concentrations between 0 and 10 % LEL.
Ideal system solution
The sensors are based on the catalytic bead (pellistor) detection principle. They contain poison-resistant Dräger pellistors that have been tested and proven over many years. The impact-resistant junction box (EEx e) is constructed from fibre-glass reinforced polyester. Combined with a suitable 4 to 20 mA control unit, the transmitter Dräger PEX 3000 gives ideal operational reliability and system availability.

Product Information

Product information: Dräger PEX 3000 (PDF)

The transmitter Dräger PEX 3000 is a gas detector for the continuous monitoring of flammable gases and vapours in the ambient air.

Accessories

kalibrierkammer_st-5654-2006.jpg

Calibration chamber

A metal chamber to vaporise combustible liquids to develop vapours (e.g. acetone, benzene, hexane, nonane etc.) Used to for zero-point tests and calibration.

Order No.: 68 02 206

kalibrieradapter_st-5678-2006.jpg

Calibration Adapter

Adapter for test of zero point and calibration for transmitters with electrochemical sensors (not type L), catalytic bead sensors (Pellistors) and the transmitters of the type Dräger Polytron IR CO2 and Dräger Polytron IR Ex HC.

Order No.: 68 06 978

spritzschutz_st-5687-2006.jpg

Splash guards

Guards the DrägerSensors of transmitters with electrochemical sensors (not type L), catalytic sensors (pellistors) and transmitters of type Polytron IR CO2 and Polytron IR Ex HC against splashing water.

Order No.: 68 07 549

Remote Calibration Adapter

Remote calibration adapter

For calibrations of transmitters with electrochemical sensors (not type L), catalytic sensors (pellistors) and transmitters of type Polytron IR CO2 and Polytron IR Ex HC that are mounted in difficult to access positions.

Order No.: 68 07 955

System Components

d-1119-2010
Catalytic Bead DrägerSensors

The Dräger Catalytic Bead Sensors is designed for the continuous monitoring and detection of combustible gases and vapours – with different versions for different applications or concentrations.

regard_2-669-95.jpg
Dräger REGARD control system

Tried and tested thousands of times and infinitely flexible. The modular Regard control system can be individually adapted to any monitoring task. Suitable for SIL 2 systems, the Regard system is also ATEX approved, and meets EMC directive standards.

Regard-3900.jpg
Dräger REGARD 3900

The Regard 3900 is a standalone, autonomous control system for up to 16 gas detectors. It is fully configurable and monitors the concentration of toxic gases, oxygen and combustible gases and vapours.

regard2400_st-5647-2006.jpg
Dräger REGARD 2400 and REGARD 2410

Whether they are mounted to a wall or integrated in the switch cabinet - the flexible small control units Regard 2400 and Regard 2410 reliably monitor the concentration of toxic gases and oxygen as well as combustible gases and vapours.

regard_1_st-335-2004.jpg
Dräger REGARD-1

Robust, reliable and very cost effective. The compact Regard-1 is a complete standalone system for the control of a single gas detector; suitable for monitors of toxic gases, oxygen, combustible gases and vapours.

Related Products

Flammable Detection

draegersensorir_st-8821-2005.jpg
DrägerSensor IR

Upgrade from Catalytic bead to infrared technology with ease using the DrägerSensor IR. The Sensor IR can replace catalytic ex-sensors (pellistors) from the majority of manufacturers without replacing controllers, cables, junction boxes or control systems.

pir3000_st-8822-2005.jpg
Dräger PIR 3000

The Drager PIR 3000 is an explosion proof infra red gas detector for the continuous monitoring of flammable gasses and vapours. With a GRP Junction box, 316 stainless steel enclosure and excellent measuring performance, the PIR 3000 offers unsurpassed price performance ratio.

polytronir_st-5651-2004.jpg
Dräger Polytron IR

The Polytron IR is a SIL 2 approved explosion proof infrared gas detector for the continuous monitoring of flammable gasses and vapours. With a 316 stainless steel enclosure and drift free heated measurement optics, it is built for the harshest industrial and offshore applications.

polytron_pulsar_st-3932-2005.jpg
Dräger Polytron Pulsar 2

The Dräger Pulsar 2 is an open path infrared gas detector. Representing the very latest advances in open pat technology – the Dräger Polytron Pulsar 2 is intended for the detection of a range of gaseous hydrocarbons. This includes the alkane series from methane to hexane, propylene, ethylene, methanol and ethanol. Equipped with either a terminal box or a certified cable entry point, the detector incorporates flexible installation.

Flame Detection

flame1700_st-341-2004.jpg
Dräger Flame 1700

The Dräger Flame 1700 is an explosion-proof ultraviolet flame detector for detection of fires in substances that emit ultraviolet radiation such as hydrogen, silicon hydride (silane) or metals. The Flame 1700 offers reliable and fast detection of flames with high immunity to false alarms

flame2300_st-341-2004.jpg
Dräger Flame 2300

The Dräger Flame 2300 is an explosion-proof combined UltraViolet/InfraRed flame detector, which detects fires of substances that emit infrared and ultraviolet radiation such as hydrocarbon fuels. The Flame 2300 offers reliable and fast detection of flames with high immunity to false alarms

Toxic Detection

polytron3000_st-3811-2003.jpg
Dräger Polytron 3000

The Dräger Polytron 3000 is an intrinsically safe gas detector for the continuous monitoring of toxic gasses and oxygen. High measuring accuracy alongside simple mounting and very easy operation. The Polytron 3000 is ideally suited to the measuring of toxic gases and oxygen in a wide range of applications.

Dräger PSD 3000
Dräger PSD 3000

The Dräger PSD 3000 is a sampling unit for continuous sampling of gas/air mixtures. In combination with Dräger Gas Transmitter, a remote sampling system can be designed for gas monitoring.

Control Systems

regard_2-669-95.jpg
Dräger REGARD control system

Tried and tested thousands of times and infinitely flexible. The modular Regard control system can be individually adapted to any monitoring task. Suitable for SIL 2 systems, the Regard system is also ATEX approved, and meets EMC directive standards.

Regard-3900.jpg
Dräger REGARD 3900

The Regard 3900 is a standalone, autonomous control system for up to 16 gas detectors. It is fully configurable and monitors the concentration of toxic gases, oxygen and combustible gases and vapours.

Literature

Brochure: Gas List 2011 (PDF)

List of detectable gases and vapours.

Brochure: More than the sum of their components (PDF)

For over 70 years, Dräger has been one of the technology leaders in gas detection.

Brochure: At the heart of gas detection systems (PDF)

When there’s danger in the air ... this can quickly pose a high risk to humans, the environment, and all types of property and systems. Recognize the threat before it is too late.

Brochure: Functional Safety and gas detection systems (PDF)

Safety Instrumented Systems are used to reduce the risk for the protection of people, plants, and environment.

Brochure: Explosion protection and gas detection systems (PDF)

Explosion hazards mostly arise from flammable gases and vapours. Instead of avoiding their ignition by explosion protection measures it may be preferable to detect them before they become ignitable.